Classe Audio SSP-30 MKII Stereo Amplifier User Manual


 
5.5 TRIGGER SETUP:
There are three Voltage Triggers on the SSP-30 MKII. They are used to turn associated equipment on and off.
These displays show that you have accessed the Trigger setup sub-menu and
highlighted Trig1 sense. You can scan through the available choices by pressing
repeatedly the \/ and /\ buttons on the remote. When the selection you wish to adjust
is highlighted press the < or > key to scroll through the choices. To memorize and
Exit highlight Exit and press the ENTER key.
Trigger setup
Trigger1 sense Power On
- polarity Posit.
- delay No
- duration Infin.
Trigger 2 sense: Power On
- polarity Posit.
- delay No
- duration Infin.
Exit
Trigger setup
Trig1 sense: Power On
TV Display Panel Display
Trigger 1 controls the TRIGGER 1 voltage output and Trigger 2 controls the TRIGGER 2 and TRIGGER 3 outputs.
Trigger 2 and Trigger 3 always turn On or Off at the same time. Use the \/ and /\ keys to select and use the < and >
keys to cycle through the available choices. The following applies to both Trigger 1 and Trigger 2.
5.5.1 Trigger sense selects what event will activate the Trigger output. Set “sense” to Power On to activate the
trigger when switching out of STANDBY (and de-activate it when returning to STANDBY). Alternatively the
trigger output may be activated when a particular Source is selected.
5.5.2 Trigger polarity sets the polarity of the trigger output. “Posit.” provides a +12V DC output when the trigger is
active and no voltage when inactive. “Negat.” sends no voltage output when the trigger is active and +12V
when inactive.
5.5.3 Trigger delay sets a delay between the “sense” signal and the trigger output voltage changing. The delay may
be set to various times from 1 second to 3 minutes or to “No” which gives no delay.
5.5.4 Trigger duration sets the period (duration) that the trigger output is active. The trigger duration may be set to
various times from 10ms (milliseconds) to 3 minutes, or to “Infin.” which keeps the trigger active while the
"sense" condition prevails.
Exit returns to the main menu
24