B&K CT300 Stereo Receiver User Manual


 
POWER SUPPLY IS CURRENT LIMITED TO 1 AMP PER EVERY THREE ZONES
The six zone receiver has two zone/controller cards, each is identical to the single controller card in a three
zone receiver. Each card has its own independent 1 amp power supply with built in current limiting protection.
You cannot draw more than 1 amp from each of the cards (a card is the vertical strip of zone and common
control connections). The control outputs are current limited to 200mA.
CT310/300 has one power supply card for keypads, IR sensors and 12VDC control outs. Anything connected
to the +12V zone keypad output, a zone control out or a common control out must have its power consump-
tion noted and added up. The total must not draw more than 1 amp for a CT310/300.
12V Power Supply
BK&
SBIMPLY ETTER!
16
ZB
ZE
+12V
GND
RS232 XMIT
CTRL OUT
DATAIN
ZCZF
+12V
GND
RS232 XMIT
CTRL OUT
DATAIN
CONTROL
ZA
ZD
+12V
GND
RS232 XMIT
DATAIN
CTRL OUT
21
RS232
12V
GND
IN
-
IN
-
OUT
IN +
12V
GND
IN
-
IN
-
OUT
IN +
COMMON
CTRL I/O
COMMON
CTRL I/O
OUT
LEFT CONTROL CARD
Fam Rm Keypad 75ma
Fam Rm Sensor 50ma
Fam Rm Screen Relay 200ma
Kitchen Keypad 75ma
Bedroom Keypad 75ma
Bedroom TV Lif
t 200ma
Total 675 ma
RIGHT CONTROL CARD
Liv Rm Keypad 75 ma
Patio Keypad 75 ma
Den Keypad 75 ma
Den Sensor 50 ma
Total 275 ma
Adding Additional Keypads in the Same Zone.
When rooms are interconnected or are open to each other (for example: interconnecting family room, kitchen,
and dining areas are common in many homes) you may opt to expand a zone to include several rooms.
Many keypads can be connected in a daisy chain from the master keypad in that zone. The master is the
keypad which is home run back to the CT Receiver. To daisy chain keypads, simply connect a CAT5 cable
terminated into RJ-45 between the two keypads. All the chained keypads need be programmed separately .
Daisy-chained keypads can be programmed for independent zone control using the appropriate code-set.
The home run (master) keypad is connected using the MASTER [IN] on the keypad back panel. From the
Master Keypad's SLAVE[OUT] connect to the second keypad's MASTER [IN]. You can continue the daisy-
chain to as many as four keypads per zone control terminal. When programming daisy chained keypads,
each keypad must be programmed separately. Always program chained keypads in series order start-
ing with the Master keypad, then the first slave, etc.
Master
Slave