Specifications
Table 1-2. AmpliCenter Specifications
Capacities
■ D20: up to 20 Watts total speaker load
■ D100: up to 100 Watts
■ D300: up to 300 Watts
Dimensions and
■ All models: 3-1/2" (8.9 cm) high x 19" (48.25 cm) wide x 5" (12.7 cm) deep
Weights
■ D20: 5 lbs (11 Kg) , D100 and D300: 6 Ibs (13 Kg)
RJ-11 Jack
■ Talk battery: 24 volts, loop start or ground start, negative voltage ring lead
Specifications
■ Impedence: 600 Ω
Temperature
■ -10 to +40 deg. C. (14°F to 104°F) operational; to +50 deg. C. (122°F) with forced air
Range:
■ -20 to +70 deg. C. (28°F to 158°F) storage and shipment
Humidity Range:
■ 5% to 95% (non-condensing) storage/shipment and operation
Environmental
■ Locate in an area free of excess moisture, corrosive gases, dust, and chemicals.
Requirements
Electrical
■ 100-250 VAC, 50/60 Hz, lamp, 3-prong outlet separate ground
■ Outlet must not be controlled by an on/off switch
■ Grounding:
A. Use the power cord supplied with the unit, or an equivalent cord that meets applicable
safety codes. Do not cut or remove the third wire ground prong.
B. The attachment-plug receptacles in the vicinity of the product or system are all to be of a
grounding type, and the grounding conductors serving these receptacles are to be
connected to earth ground at the service equipment.
1-10 Overview