3M 2210E Stereo System User Manual


 
Page 10
DETERMINING CABLE DEPTH AND CURRENT
Place the Receiver Antenna on the ground directly above the cable with
the handle parallel to the path. Press and the display will indicate the
cable depth and relative current
. Current is displayed in the lower left
corner of the display. Press twice to continue tracing. You may also
press to return to Trace mode.
LOCATING AN ACTIVE DUCT PROBE (ADP)
Press to turn the Receiver on.
Press to select the 33 kHz frequency.
With the Receiver handle perpendicular to the conduit path, locate
the ADP position by moving along the path until a peak is found.
Press when the bar graph remains either fully open or fully
closed. Refer to the ADP operating instructions for further information.
Determining ADP Depth
Place the Receiver Antenna on the ground directly above the located
ADP position maintaining the handle orientation perpendicular to the
path. Press twice to display ADP depth . To return to
trace mode, press or .