5. Remove three screws (B) from RIP board cage.
6. Remove RIP board cage.
High voltage power supply (HVPS) removal
1. Remove RIP board cage. See RIP board cage removal on
page 4-57.
2. Disconnect all connectors from HVPS.
Note: When reinstalling flat cable, ensure blue side of cable is
opposite pins on connector CN1. Flat cable pins are exposed on
only one side (opposite blue side) and must make contact with metal
pins on connector.