Yamaha ACD1 Stereo Amplifier User Manual


 
ACD1 Reference Manual
15
Panel operations
Enabling scene recall operations via EMG commands
(“5. Utility” “EMG Scene Setup”)
Specifies whether the EMG scene will be recalled when the EMG (Emer-
gency) signal is received.
The following three types of EMG signal can be received.
EMG command sent from AMX/Crestron
Input signal to the GPI IN assigned to the Emergency scene
EMG command sent from a different ACD1 unit
If you select “ALL” as the [Amp ID], the EMG Scene Setup area may indicate “Some ON.” This means that EMG scene
recall is enabled for some amplifiers but disabled for other amplifiers.
LAST MEMORY RESUME setting (“5. Utility” “Last Mem. Resume”)
This specifies whether the unit will start up in the state in which it was pow-
ered-off, or recall the scene of the scene number that was selected at power-
off.
Clock setting (“5. Utility” “Clock”)
Sets the date and time of the ACD1’s internal clock.
The seconds will be set to 00 when you finalize the time.
If Daylight Saving Time is enabled in Amp Editor, this will indicate “DST.”
Parameter Range Explanation
Amp ID 00–39, ALL Specifies the ID of the amp for which EMG scene recall will be enabled. If you select
“ALL,” the EMG scene recall enable status of all amplifiers will be switched to the
specified state.
EMG Scene Setup 00–49 Recalls the specified scene.
OFF A scene will not be recalled even if an EMG signal is received.
Parameter Range Explanation
Last Mem. Resume ON The unit will start up in the state in which it was powered-off.
OFF At start-up, the unit will recall the scene that was last recalled or stored before the
power was turned off.
Parameter Range Explanation
Date 01–31 Sets the date.
Month Jan–Dec Sets the month.
Year 00–99 Sets the year. The last two digits of the Western calendar year can be specified.
Hour 00–23 Sets the hour.
Minute 00–59 Sets the minute.
å
Amp ID: 01
OFF
NOTE
å
Last Mem.Resume
ON
å
Clock DST
01-Oct-09 16:43
NOTE