Loudness Maximizer
7
Quick Start
Flow Chart
The signal analysis computes
control data for the
Compressor and Limiter and
calculates the Possible as well
as the Done loudness increase
Possible:The LED bar shows
the possible loudness
increase
Done:The LED bar shows how
much % of the DESIRED GAIN
have been realized
The Compressor operates
with a static (no-knee)
characteristic for most unob-
strusive compression
DESIRED GAIN:Adjusts the
desired loudness increase
Density:Controls the amount
of compression
The Limiter is equipped with
SOFT-HARD sound control
and the BOOST function
All controls are in the start-off positions:
DESIRED GAIN 0; SOFT-HARD -9;MORE DENSITY 0.
1.Press ACTIVE.LED illuminates.
2. Watch the Possible LED chain and adjust the shown value
with the DESIRED GAIN (for most unobstrusive operation the
Possible LED chain should not show negative values.
3. If more loudness is wanted, turn the SOFT-HARD to higher
values (i.e.-3).The Possible LED chain shows you the new free
loudness headroom that you ad to the previously adjusted
DESIRED GAIN value.
4. To increase the density of your source material turn up the
MORE DENSITY control.
AUDIO
signal
analysis
compressor
AUDIO
limiter
Possible
display
Done
display
Desired
encoder
Density
encoder
Boost
switch
Soft/Hard
encoder