Sony STRDG910 Stereo Receiver User Manual


 
38
GB
D:\CANNES\SONY_HA\JOB 2007\STR-
DG910\IM_910_CEL\Data_CEL\GB_data\GB03CON_STR-DG910-CEL.fm
masterpage: Left
STR-DG910
3-094-430-31 (1)
* xxx represent a speaker channel.
FL Front Left
FR Front Right
CCenter
SL Surround Left
SR Surround Right
SBL Surround Back Left
SBR Surround Back Right
SW Sub woofer
Tip
Depending on the position of the sub woofer, the
measurement results for polarity may vary.
However, there will be no problems even if you
continue to use the receiver with that value.
Select “8-A. CAL” in the amplifier menus. For
details on adjusting the parameters, see
“Navigating through menus” (page 44) and
“Overview of the menus” (page 45).
x AUTO CAL (Auto Calibration on/
off)
A.CAL NO
The Auto Calibration function is turned off.
A.CAL YES
The Auto Calibration function is turned on.
To start Auto Calibration, press
.
x CAL TYPE (Calibration type)*
•ENGINEER
Sets the frequency characteristics to a set
that matches that of the Sony listening room
standard.
•FLAT
Makes the measurement of frequency from
each speaker flat.
FRT REF
Adjusts the characteristics of all speakers to
match the characteristics of the front
speaker.
x CAL LOAD (Preset measurement
loading)*
LOAD NO
Select this when you do not want to load the
saved Auto Calibration result.
LOAD YES
Select this when you want to load the saved
Auto Calibration result.
* You can select this parameter only when you have
performed the Auto Calibration and saved the
settings.
Display Explanation
xxx* IN The speaker is in phase.
xxx* OUT The speaker is out of phase. The
“+” and “–” terminals of the
speaker may be connected the
other way around. However,
depending on the speakers,
xxx OUT” appears on the
display even though the speakers
are connected properly. This is
because of the speakers’
specifications. In this case, you
can continue to use the receiver.
A. CAL menu parameters