Synchronizing the transmitter with the EK 2000 IEM receiver
31
Operation without
network
̈ First carry out the Easy Setup Sync function (see table on page 16, left-hand column).
The transmitter is set to a suitable frequency.
̈ Then carry out the Sync function once for each transmitter/receiver pair (see table on
page 16, right-hand column).
This establishes a transmission link between the transmitter and the receiver.
Using freely selectable transmission frequencies
You can also freely select the frequencies and store these frequencies in the frequency banks
“U1” to “U6”.
If you want to use the frequency banks “U1” to “U6”:
̈ Make sure to use transmitters and receivers from the same frequency range (see page 4
and the type plates of the devices).
̈ Set each transmitter to the same frequency bank.
̈ On one of the transmitters, select a channel within this frequency bank (see page 25).
̈ Assign this channel one of the calculated transmission frequencies (see page 25).
̈ Synchronize a receiver with your transmitter ( , see page 16).
OR
̈ Manually set the receiver to the same frequency bank, channel and frequency that you set
on the transmitter.
̈ Repeat for the remaining transmitters and receivers as described above.
To ensure that the desired frequencies are intermodulation-free:
̈ Contact your Sennheiser partner (see www.sennheiser.com).