Sennheiser EK 2000 IEM Radio User Manual


 
28
Synchronizing a transmitter with the diversity receiver
Synchronizing a transmitter with the
diversity receiver
Setting the transmitters to intermodulation-free
channels (Easy Setup Sync)
Upon delivery, the SR 2000 IEM or SR 2050 IEM transmitter and the diver-
sity receiver are synchronized with each other. If, however, you cannot
establish a transmission link between transmitter and diversity receiver,
you first have to use the diversity receiver to determine intermodulation-
free channels and then transfer these channels to the transmitters.
In doing so, no transmission links are established.
̈ On all transmitters, call up the “Easy Setup” menu item.
Easy Setup Sync” appears on the display panels of the transmitters.
The RF signals of the transmitters are deactivated. The transmitters
await the transfer of a channel and a frequency bank via their infra-red
interfaces.
̈ With a diversity receiver, perform a frequency preset scan to scan the
frequency banks for unused channels (“Scan New List”, see page 21).
̈ Select a frequency bank with a sufficient number of unused channels
and a channel on this receiver (“Current List”, see page 21).
When synchronizing the SR 2000 IEM or SR 2050 IEM transmitter
with a diversity receiver, please observe the following:
̈ Only use a transmitter and a diversity receiver from the same
frequency range (see the type plates on the transmitter and
the diversity receiver).
̈ Make sure that the desired frequencies are listed in the
enclosed frequency information sheet.
You can also contact your Sennheiser partner who will be
pleased to calculate intermodulation-free frequencies for you.
̈ Make sure that the desired frequencies are approved and
legal in your country and, if necessary, apply for an operating
license.