Attachment of Ferrite to Data Cable of FT85081 Transmitter
A snap-on ferrite is supplied with the FT85081MSTR,
FT85081SSTR, and FT85081SFCR transmitters. The ferrite
must be attached to the data cable of the transmitters to
comply with FCC and CE emissions requirements.
After data connections are made to the data connector on
the transmitter, attach the ferrite to the data cable. When
attaching the ferrite to the cable, position the ferrite as
close as possible to the transmitter.
NOTE: The ferrite should fit securely around the cable.
If the ferrite is loose and slides along the cable, loop the
cable through the ferrite before closing the ferrite.
If, however, the thickness of the cable prevents the ferrite
from closing, use a tie wrap to hold the ferrite in place
rather than looping the cable.