Note:
For use of MD cartridge type laser power meter, remove the intermediate cabinet before
perform the laser power adjustment (as for the method of disassembly, refer to “5. Operation
checks and main component replacement procedures”.).
6.2. Laser power adjustment, Off-set automatic adjustment and
Playback-only disc/magneto-optical disc auto- adjustment
6.2.1. Enter the adjustment mode
1. Set the battery and connect the remote controller.
2. Turn off the power, and switch main unit’s HOLD switch off.
3. Press the buttons of the remote controller in order from 1 to 4 (as
shown in Fig. 5 ).
Fig. 5
4. When the adjustment mode is activated, “T0E**” will be displayed
on the LCD of remote controller and unit. After “T0E**” is
displayed, select the desired adjustment itemwith the button
or button of the remote controller. (If it is not displayed,
perform the procedures written above again.)