SYSTEM DESIGN WIRING FOR RFG
The RFG has two RJ-45 connections for wiring into the system. The connection used
depends on the mode and overall system design.
A MASTER RFG CONNECTED TO A NILES NETWORK-BASED MULTIZONE RECEIVER:
A RFG with dipswitches set for Master Base mode must be connected directly to the
MultiZone receiver using CAT-5 cable as detailed in
Figure 2. No power supply is needed.
A master RFG can be wired with repeater RFGs by wiring the CAT-5 cable from the
MultiZone Receiver’s Communications port to the System connection of the first RFG, and
then from the first RFG’s Keypad connection port to the System connection of the next RFG.
Two RFGs can be daisy chained to the receiver without an additional power supply. A Niles
Power supply (FG01035) can be used to power up to four RFGs on a single CAT-5 cable run.
Figure 2. A master RFG connected to a MultiZone receiver
Set as
Master Base
Niles Network Based
MultiZone Receiver
CAT-5 Cable



Niles Network Based
MultiZone Receiver



Master
Base
Repeater
Base
Repeater
Base
Keypad
Connection






System
Connection
Figure 3. Daisy-chain wiring and powering of 3 RFGs
CAT-5 Cable