A REPEATER RFG NOT WIRED TO A MULTIZONE RECEIVER
A RFG set for Repeater Base Mode and not connected to a MultiZone receiver (stand
alone) must have an optional power supply connected.
A RFG SET FOR WIRELESS KEYPAD MODE
A RFG set for Wireless Keypad must have the optional power supply and a CAT-5 cable
connected to the keypad.
A RFG EXTENDING THE RADIO OF THE NILES HT-MSU
The RFG dipswitches should be set for Master Base mode and an optional power supply
must be used. Connect from the HT-MSU Expansion port to the RFG’s Keypad connection
(Figure 6). See more detail in HT-MSU manual, available online at www.nilesaudio.com).
Figure 4. RFG wired as a stand
alone repeater
RFG
Figure 5. RFG in wireless keypad configuration
RFG
Keypad
Port