Niles Audio RFG Radio User Manual


 
12
TROUBLESHOOTING
The set-up dipswitches allow the RFG to be pre-configured for its role in the system RF
mode design. With this in mind, troubleshooting the RFG comes down to two main issues:
1) SET-UP ISSUES
2) HARDWARE ISSUES
SET-UP ISSUES
PROBLEM:
1.
Wrong Set-up
If the RFG is set-up for the wrong operation mode, the system will not operate
properly. The symptoms could include: Power LED flickers or is off, intermittent
operation, or no operation.
SOLUTIONS:
• Check the dipswitch settings
• If set for wireless keypad mode, check the RF channel by accessing through
the keypads installer settings mode
• If dipswitches are set for Not Assigned mode, the RFG must be configured
using the Niles QuickConfig software
HARDWARE ISSUES
There are two basic issues that can prevent proper operation of the RFG.
These issues are presented in the order of probability.