Module name = Signal splier
Descripon = The signal splier divides the signal into 2 streams. Each runs in parallel using it’s
own set of modules. In the “signal merge” module, these two streams are mixed into one signal
again. You can only use signal splier once per preset.
Module name = Frequency analyzer
Descripon = The frequency analyzer can scan the audio in real me and present the frequency
content on a live display. The update speed can be switched between 50 ms and 500 ms. The
analyzer can create up to three snapshots and overlay them over each other. By hovering your
mouse over the graph you can get an accurate readout of that posion. The an-aliased display
yields a very accurate picture.
Module name = Leveler
Descripon = A ulity module that can be inserted wherever you wish to monitor or change the
volume levels. The module monitors both the le & right channels. This module has a volume
adjust and a “Learn” buon to automacally adjust level to 0dB.