Icom IC PCR100 Stereo Receiver User Manual


 
29
5
SCAN OPERATION
Auto memory write scan
Auto memory write scan does the same as the programmed
scan and then writes paused signal frequencies into memory
channels of a specied memory bank. Scan edges must be
programmed in advance. (p. 28)
DUsing the multi-function receiver screen
q Make sure the squelch is set to the threshold point. (closed
condition)
w Click the [SET] button to call up the setting screen if it is
not displayed.
e Click the [Program SCAN] tab to show the program list.
r Select the programmed scan edges to be scanned with the
mouse, then click the [Auto MW SCAN] tab.
t Select a memory bank to be written.
To clear the selected memory bank contents, click [All Clear].
y Click the [AUTO] button to start auto memory write scan.
•“AUTO”flashes while scanning.
u To cancel the scan, click [STOP] or [AUTO].
DUsing the simple function receiver screen
q Make sure the squelch is set to the threshold point. (closed
condition)
w Call up the setting screen if it is not displayed.
Click the [MENU] button and select the Function Setting (SET).
When the scan controller screen is in use, click the [SET] button
on the screen.
e Click the [Program SCAN] tab to show the program list.
r Select the programmed scan edges to be scanned with the
mouse, then click the [Auto MW SCAN] tab.
t Select a memory bank to be written.
To clear the selected memory bank contents, click [All Clear].
y Call up the scan controller screen if it is not displayed.
Click the [MENU] button and select the Scan Controller.
u Click the [AUTO] button to start auto memory write scan.
•“Auto MW SCAN”flashes while scanning.
i To cancel the scan, click [STOP] or [AUTO].
[AUTO]
[STOP]
[SET]