Harman-Kardon AVR 510 Stereo Receiver User Manual


 
24 SYSTEM CONFIGURATION
System Configuration
Before beginning the output level adjustment
process, make certain that all speaker connec-
tions have been properly made. The system
volume should be set to the level that you will
use during a typical listening session. Finally,
make certain that the
Balance Control * is
set to the center 12 oclockposition.
Using EzSet
Harman Kardons exclusive EzSet remote makes
it possible to quickly and accurately set the
AVR 510s output levels without the use of a
sound pressure meter, although manual adjust-
ment is also available. However, for the easiest
set-up, follow these steps while seated in the
listening position that will be used most often:
1. Make certain that all speaker positions
have been properly configured for their
largeor smallsettings (as outlined
above) and turn off the OSD system if it is
in use.
2. Adjust the volume so that it is at
-15,as
shown in the on-screen display or
Main
Information Display
Y.
3. Hold the remote in front of you at arms
length, being sure not to cover the
EzSet
Sensor Microphone
at the top of
the remote.
4. Press and hold the
SPL Indicator Select
button for three seconds. Release it
when the
Program/SPL Indicator c
stops flashing and you hear a test noise
from the front left speaker.
5. At this point, EzSet will take over, adjusting
the output level of each channel so that
when the process is complete all levels will
be equal and at the set reference point.
This process may take a few minutes,
depending on the extent of adjustment
required.
6. During the adjustment, you will see the
location of the channel position being
adjusted appear in both the on-screen
display (if connected) and the
Main
Information Display
Y, alternating with
a readout of the output setting, relative to
the reference volume level. As the adjust-
ment proceeds, a few things will happen
simultaneously:
The channel position being adjusted will
flash in the
Speaker/Channel Input
Indicators
Q. If the test noise is heard
from a channel other than the one shown
in the Indicator, there is an error in the
speaker connections. If this is the case,
press the
Test Button i TWICE to
stop the adjustment. Then, turn the unit
off and verify that all speakers are con-
nected to the proper
Outputs .
As the individual channels are set, the
channel name and the adjustment offset
will appear in the on-screen display (if
connected) and the
Main Information
Display
Y. While the level is changing,
the
Program/SPL Indicator c will
change colors to reflect the output level
in relation to the reference. A red indica-
tion shows that the level is too high,
while an amber indication shows that the
level is too low. When the indicator is
green, the level is correct, and the test
noise will move to the next channel.
While adjustments are being made, the
red LED under the
AVR Selector f
will flash. This is normal, and indicates
that EzSet is operating.
7. After the test noise has circulated once
through each channel, it will send the tone
to each channel once again, to verify the
settings.
8. After two complete circulations of the
tone, the levels are set.The
Program/SPL
Indicator
c will remain green at each
channel. Upon completion of the second
circulation, the
Program/SPL Indicator
c will flash green twice and then go out.
The tone will stop and the AVR 510 will
return to normal operation.
If you find that the output levels chosen by
EzSet are either uncomfortably low or high, you
may repeat the procedure. Return to Step 2 and
adjust the master volume either slightly higher
or lower to accommodate your particular room
layout and your tastes. You may repeat this pro-
cedure as many times as necessary to achieve a
desired result. In order to prevent possible dam-
age to your hearing or your equipment, we
emphasize that you should avoid setting the
master volume above 0dB.
Manual Output Level Adjustment
Output levels may also be adjusted manually,
either to set them to a specific level with an
SPL meter, or to make fine tuning adjustments
to the levels obtained using the EzSet remote.
Manual output level adjustment is most easily
done through the
OUTPUT ADJUST
menu (Figure 7). If you are already at the main
menu, press the
¤
button n until the on-
screen
cursor is next to the OUTPUT
ADJUST
line. If you are not at the main
menu, press the
OSD button v to bring up
the
MASTER MENU (Figure 1), and then
press the
¤
button n three times so that the
on-screen
cursor is next to the OUTPUT
ADJUST
line. Press the Set button p to
bring the
OUTPUT ADJUST menu
(Figure 7) to the screen.
Figure 7
As soon as the new menu appears, you will
hear a test noise circulate from speaker to
speaker in a clockwise direction around the
room. The test noise will play for two seconds
in each speaker before circulating, and a blink-
ing on-screen cursor will appear next to the
name of each speaker location when the sound
is at that speaker.
NOTE: Remember to verify that the speakers
have been properly connected. As the test noise
circulates, listen to make certain that the sound
comes from the speaker position shown in the
Main Information Display Y. If the sound
from a speaker location does NOT match the
position indicated in the display, turn the
AVR 510 off using the
Main Power Switch
1 and check the speaker wiring to make cer-
tain that each speaker is connected to the cor-
rect output terminal.
After checking for speaker placement, let the
test noise circulate again, and listen to see
which channels sound louder than the others.
Using the front left speaker as a reference,
press the
/
buttons o on the remote
to bring all speakers to the same volume level.
When one of the
/
buttons is pushed, the
test noise circulation will pause on the channel
being adjusted to give you time to make the
adjustment. When you release the button, the
circulation will resume after five seconds.
31
* OUTPUT ADJUST *
FRONT LEFT : 0dB
CENTER : 0dB
FRONT RIGHT: 0dB
SURR RIGHT : 0dB
SURR LEFT : 0dB
RETURN TO MENU
36
39