Extron electronic USP 405 Stereo System User Manual


 
Serial Communication, cont’d
USP 405 • Serial Communication3-6
Command/response table for SIS commands (continued)
Command ASCII Command Response Additional description
(host to USP) (USP to host)
View the freeze status F
X9
Show the freeze status.
Example: F 0
Pixel phase
Set a specific pixel sampling phase
X1
*
X21
U
X1
Phs
X21
Specify the pixel sampling
phase.
Example: 1*17U 1Phs17
Set the sample phase to 17 for
input 1.
Increment sampling value
X1
+ U
X1
Phs
X21
Increase the phase value.
Decrement sampling value
X1
- U
X1
Phs
X21
Decrease the phase value.
View the sampling value
X1
U
X21
Show the pixel sampling
phase.
Front panel security lockout (executive mode)
Disable 0X Exe0 Adjustments & selections can
be made from the front panel.
Enable (lock image adjustments) 1X Exe1 Lock front panel adjustments;
adjust image via RS-232 only.
View the executive mode status X
X9
Show executive mode status.
Example: X 0 Executive mode off.
Test pattern
Select test pattern
X12
J Tst
X12
Select a test pattern.
Select test pattern
X12
j Tst
X12
Select a test pattern.
View test pattern J/j
X12
Show the test pattern.
Example: J 0 Test pattern off.
Scaler output rate
Set the output rate
X7
*
X20
= Rte
X7
*
X20
Select a global scaler output
scan rate.
View the output rate =
X7
*
X20
Show the global scaler output
rate.
Set the output rate per input
X7
*
X20
*
X5
= Rte
X7
*
X20
Select a scaler output scan rate
for input
X5
. An input of 0
sets a global output rate for all
inputs.
View the output rate per input
X5
=
X7
*
X20
Show the scaler output rate.
When input
X5
= 0, the global
output rate (prior to setting
the rate using the per input
command) is displayed.
Firmware version, part number & information requests
Query firmware version number Q/q x.xx Show the controller firmware
version.
Request part number N/n xx-xxx-xx Show the USP 405’s part #.
Request general info. I/i (See below) Show the USP 405’s status.
Vid
X1
•Hrt
X15
•Vrt
X15
•Std
X16
•Pre
X19
Zap (reset to default settings)
Zap all USP 405 settings
Esc
zXXX ZpX Reset everything: all settings,
and adjustments to the factory
default.