Extron electronic MTP 15HD Stereo Receiver User Manual


 
As an alternative, an Extron PS 124 Universal 12 VDC Power Supply (part number
60-1022-01) can power multiple MTPs or other Extron 12 VDC devices using only one AC
power connector.
Twisted Pair Cable Termination
Figure 9 details the recommended termination of twisted pair cables with RJ-45 connectors
in accordance with the TIA/EIA T568A or TIA/EIA T568B wiring standards. You can use either
standard with CAT 5, 5e, and 6 cable, but ensure that you use the same standard on
both ends of the cable.
RJ-45
Connector
Insert Twisted
Pair Wires
12345678
Pins:
Pi
nS
ignal
1 Red/V. sync +
2 Red/V. sync -
3
Green +
4
Blue/H. sync +
5
Blue/H. sync -
6
Green -
7
RS-232 +
8
RS-232 -
Wire color
White-green
Green
White-orange
Blue
White-blue
Orange
White-brown
Brown
Wire color
TIA/EIA T 568 ATIA/EIA T 568 B
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
NOTE:
When using Enhanced Skew-Free
AV UTP cable, use the TIA/EIA T568A
standard only.
Figure 9. Twisted Pair Cable Termination Diagram
NOTES:
RJ-45 termination with CAT 5, 5e, or 6 cable must comply with the
TIA/EIA T568A or TIA/EIA T568B wiring standards for all connections.
RJ-45 termination with Skew-Free AV UTP cable must comply with
TIA/EIA T568A only.
For proper grounding of shielded twisted pair cable, ensure the shield around
each wire pair are all tied to the RJ-45 connectors on both ends, in accordance with
the connector specifications provided by the manufacturer.
Extron Enhanced Skew-Free AV cable is not recommended for
Ethernet/LAN applications. This cable is specially designed for compatibility with
Extron Twisted Pair products that are wired using the TIA/EIA T568A standard.
The green, brown, and blue wire pairs of this cable have virtually identical lengths
and should be used to transmit the RGB signals.
The orange wire pair of this cable has a different length and should not be used to
transmit the RGB signals.
MTP 15HD RS Series • Installation and Operation 13