Extron electronic MTP 15HD Stereo Receiver User Manual


 
e
Pre-Peak switch — The Pre-Peak switch alters the twisted pair signal output to correct
for long cable runs. See the table on page 4 for suggested switch settings based on the
transmitted video format and transmission distance.
NOTES:
Use the internal jumpers to enable bidirectional communication (see
"Pre-Installation — RS-232 Jumper" on page 5).
The length of the exposed wires in the stripping process is critical. The ideal length is
3/16 inches (5 mm). If the exposed section is longer, the exposed wires may touch,
causing a short circuit between them. If it is shorter, the wires can be easily pulled
out, even if tightly fastened by the captive screws.
Do not tin the wires. Tinned wire does not hold its shape and can become loose over
time.
f
Output connector Connect one end of a twisted pair cable to this RJ-45 female
connector on the transmitter. Connect the free end of the same twisted pair cable to
the RJ-45 female connector on the receiver. See "Twisted Pair Cable Termination" on
page 13 to wire the RJ-45 connectors.
ATTENTION: Potential damage to property.
Do not connect these devices to a computer data or telecommunications network.
MTP 15HD RS Series • Installation and Operation 9