Emerson 00809-0100-4514 Satellite Radio User Manual


 
Reference Manual
00809-0100-4514, Rev BA
January 2008
Rosemount 1154
6-8
ORDERING INFORMATION
Table 6-1. Transmitter Design Specifications.
Model Description
1154 Alphaline Pressure Transmitters for Nuclear Applications, IEEE Std 323-1974 and IEEE Std 344-1975
Code Pressure Measurement
DP
HP
GP
Differential Pressure, 2,000 psig (13.8 MPa) Static Pressure Rating
Differential Pressure, 3,000 psig (20.68 MPa) Static Pressure Rating
Gage Pressure
PRESSURE RANGES at 68 °F
Code
Rosemount 1154DP
(Differential)
Rosemount 1154HP
(Differential)
Rosemount 1154GP
(Gage)
4 0–25 to 0–150 inH
2
O
(0–6.22 to 0–37.3 kPa)
0–25 to 0–150 inH
2
O
(0–6.22 to 0–37.3 kPa)
0–25 to 0–150 inH
2
O
(0–6.22 to 0–37.3 kPa)
5 0–125 to 0–750 inH
2
O
(0–31.08 to 0–186.4 kPa)
0–125 to 0–750 inH
2
O
(0–31.08 to 0–186.4 kPa)
0–125 to 0–750 inH
2
O
(0–31.08 to 0–186.4 kPa)
6 0–17 to 0–100 psi
(0–0.12 to 0–0.69 MPa)
0–17 to 0–100 psi
(0–0.12 to 0–0.69 MPa)
0–17 to 0–100 psi
(0–0.12 to 0–0.69 MPa)
7 0–50 to 0–300 psi
(0–0.34 to 0–2.07 MPa)
0–50 to 0–300 psi
(0–0.34 to 0–2.07 MPa)
0–50 to 0–300 psi
(0–0.34 to 0–2.07 MPa)
8 0–170 to 0–1,000 psi
(0–1.17 to 0–6.89 MPa)
0–170 to 0–1,000 psi
(0–1.17 to 0–6.89 MPa)
9 0–500 to 0–3,000 psi
(0–3.45 to 0–20.68 MPa)
0 0–1,000 to 0–4,000 psi
(0–6.89 to 0–27.56 MPa)
Code Output
R
(1)
(1) The Rosemount 1154 with Output Code R Electronics is also available with adjustable damping. This option is specified
by appending “N0037” to the end of the complete model number, for example, 1154DP4RAN0037.
Standard 4–20 mA
Code Flange Option
A
B
(2)
C
(2)
D
E
(2)
F
(2)
G
H
J
(2)
L
M
(2)
(2) Note: Customer assumes responsibility for qualifying connection interfaces on these options. Contact Rosemount
Nuclear Instruments, Inc. for details.
Welded
3
/8 in. Swagelok Compression Fitting Process Connection and Welded Drain/Vent Valve
¼–18 NPT Process Connection and Welded Drain/Vent Valve
¼–18 NPT Process Connection and Drain Hole (Drain/Vent Valve not supplied)
One Flange Code Option A and One Remote Seal
One Flange Code Option B and One Remote Seal
One Flange Code Option C and One Remote Seal
Two Remote Seals
Welded
3
/8 in. Swagelok Compression Fittings on Both Process Connection and Drain/Vent Connection
Welded
3
/8 in. Swagelok Compression Fitting Process Connection and ¼–18 NPT Drain Hole
One Flange Code Option H and One Remote Seal
One Flange Code Option J and One Remote Seal
Typical Model Number:1154 DP 4 R A