Parameters available for AIR 6 and AIR 15
Pink Noise:
Range: On/Off
Calibrate:
Range: -6dB to +6dB
Level calibration of the selected monitor.
Rel. Lev:
Range: -40dB to 0dB
Relative preset volume for the selected monitor.
Room Position:
Neutral
Wall
Corner
Console
C. Wall - Console Wall
C. Corn - Console Corner
Bass:
Range: -6dB to +6dB
Bass adjustment for the selected monitor
T
reble:
Range: -6dB to +6dB
Treble adjustment for the selected monitor.
Parameters of AIR Base subwoofers
Pink Noise:
Range: On/Off
Calibrate:
Range: -18dB to +6dB
Level calibration of the selected monitor.
Rel. Lev
. - (Relative Level):
Range: -40dB to 0dB
Preset volume for the selected monitor relative to the
calibrated and global volume.
LFE Low Pass
Range: On/Off
Brickwall Limiter on the LFE channel attenuating
frequencies above 120Hz.
LFE Gain
Range: -6 to +8dB
With this parameter you can boost the acoustic gain of the
LFE channel.
Polarity
Range: 0 or 180º
If the Subwoofer is correctly placed, setting the Phase
Reverse parameter at 180º should result in a full Phase
cancellation at the set Cross -over frequency. If this is not
the case - the Delay parameter should be adjusted.
Phase:
Range: 0-180°
PARAMETER DESCRIPTION
To time-compensate if the Sub is not placed according to
the ITU 775 recommendations. There are individual Phase
settings for each of the Bass Management Cross-over
frequencies. Once set, these are stored as Global settings.
Clear Setup for entire network
• Press ENTER and confirm with ENTER
LFE channel - note
Please note that in general the LFE channel should be
mixed with +10dB headroom.
If you are not able to boost your LFE monitor output from
your console, +10dB gain can be added on your AIR-Base
input. Most format encoders / decoders take the LFE boost
into account, meaning that you should leave the AIR-Base
LFE gain at 0dB when playing back a DTS or DOLBY
encoded material on your AIR system. LFE gain is set at
0dB in all factory presets, so if you need to add gain on
your AIR Base please adjust this parameter and store the
new setting in a user preset location.
Presets In General
A preset consists of the following settings:
Preset Volume
Mute status
Bass Management
X-curve setting
LFE Low Pass
LFE Gain
Parametric EQ (can be adjusted the optional PC
Installers Package only)
All other settings can be considered “global” and are not
stored with presets.
With the optional AIR PC-IP installers software you
can however create custom presets including
global parameters.
Recall
Press ENTER and use ARROW keys to select presets
Press ENTER to recall/load the selected preset
If no user-preset are stored on locations 1 to 4, presets 16
to 19 are loaded instead.
Complete preset list is available in the appendix
section.
Store
Press ENTER and select storage location using the
ARROW keys
Press ENTER again to store.
Storage location can be 1-15.
Parameter can be locked via the Installers
software. When trying to change values on a
locked parameter the display reads “Locked”.
Air_US_rev_111.qxd 16-12-2004 14:16 Page 20