Bosch Appliances LE10 Radio User Manual


 
8 en | Product information LE10 Radio Receiver
F.01U.278.517 | V2.0 | 2012.11 User Manual Bosch Security Systems
4 Dementia with
Accompany
This mode allows to connect the LE10 Radio
Receiver to a wired emergency call system, in
which the Accompany function can be
implemented. It will wait 10 seconds after
receiving a signal from a MIYS37L transmitter.
If it detects a MIYS37E transmitter in this lapse
of time, no alarm is generated. If not, Relay 1 is
activated for 2 seconds.
5 Remote control 20 wireless transmitters can be programmed.
Per sequence, only the same transmitter can
switch on and off the Relay1. A battery-low
signal is indicated by the red LED and Relay 2.
6 Open receiver No wireless transmitter needs to be
programmed. Any transmitter within reception
range of the LE10 Radio Receiver can activate
the device.
7 Open receiver with
reduced range
Same functions as in mode 6, but with
reduced range. This functionality is designed
to improve reception of transmitters located
closer to the LE10 Radio Receiver.
8 Extended MIYN46
transmitter
programming
(only with SW 1.10)
Additional MIYN46 transmitters can be
programmed. Behavior is similar to normal
mode 1, with certain differences according to
the transmitter that is activated.
9 Dual channel receiver
(only with SW 1.10)
Only MIYS37 wireless transmitters can be
programmed. Calls are indicated by Relay 1 or
Relay 2, according to the slot in which the
MIYS37 wireless transmitter is programmed. A
battery-low signal is indicated by the red LED.
Mode Name Description
NOTICE!
Factory setting is normal mode 1, in which 20 wireless
transmitters can be programmed. Calls are indicated by the red
LED and Relay 1. A battery-low signal is indicated by the red
LED and Relay 2.