![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/e0/0e0e8e8b-213d-42a5-8021-4d676a2e4a28/0e0e8e8b-213d-42a5-8021-4d676a2e4a28-bg15.png)
LE10 Radio Receiver Operation | en 21
Bosch Security Systems User Manual F.01U.278.517 | V2.0 | 2012.11
6.7.2 Reset of a battery-low indication with button T1
Device behavior
– The green LED stays permanently on.
– The red LED is already blinking every 10 seconds.
Upon pressing button T1 min. 1 second, there is a reset of the
battery-low indication:
– The red LED turns off.
– Relay 2 switches off.
6.8 Extended MIYN46 (mode 8, only with SW
1.10)
Programming and deleting of transmitters is done as in Mode 1.
Standby
– The green LED stays permanently on.
– The red LED is off.
– Relay 1 is switched off.
– Relay 2 is switched off.
When a MIYS37 transmitter, MIYS35 transmitter, MIYRAC
contact, MIYMD ManDown Sensor are activated:
– The green LED stays permanently on.
– The red LED turns on for 2 seconds.
– Relay 1 is switched on for 2 seconds.
– Relay 2 is switched off.
When a MIYN46 transmitter’s red or blue button is pressed,
or when one of its inputs is activated:
– The green LED stays permanently on.
– The red LED and Relay 1 switch on for 6 minutes or until
the green button of the MIYN46 transmitter is pressed.
– Relay 2 is switched off.
NOTICE!
If you disconnect and reconnect the power supply, the battery-
low indication will be reset as well.