ATON AH66T Radio User Manual


 
ATON AH66T INSTALLATION MANUAL
© ATON 2010 | All rights reserved. Page 37
RadioRA
®
2 Integration
In the ATON configuration software determine which Comm Port you will be using to
connect to the lighting system. Connect all RadioRA2 components according to the
RadioRA2 installation manual. Verify functionality of the RadioRA2.
Connect a Cat5 (TIA/EIA568A or B) from the selected Comm Port of the AH66T to the
DB9M-RJ45 adapter. Connect a serial cable from the adaptor to the RS-232 port of the
RadioRA2 MAIN Repeater.
The MAXIMUM total wire run length from the AH66T’s Comm Port to the RS-232 port of
the MAIN Repeater is 50’ (15m).
Figure 4-4: RadioRA 2 Connections
RadioRA feedback is only displayed on the OLED2s. It does not “pass through” to 3
rd
party controllers.