2.3 PDU Installation
2.3.1 Mechanical Attachment of PDU
The PDU should be mounted in accordance with local code using appropriate hardware. The
PDU has two mounting holes on either side, as shown in Figure 4. Below are guidelines for
standard wall mount, masonry wall mount, and rack mount of the PDU.
Figure 4. Example of PDU Standard Wall Mount
2.3.1.1 Standard Wall Mount
When mounting the PDU on a wooden or metal surface, it is recommended that it be installed
on a secure surface.
2.3.1.2 Masonry Wall Mount
When mounting the PDU on a masonry surface, it is important that the bolts (especially the
upper bolts) be located as close as possible to the center of bricks or blocks. Masonry mounting
screws are not provided.
Warning: Never install the Power Distribution Unit in a wet location or during a lightning
storm. When installing or modifying communication lines, disconnect lines at the interface
before working with uninsulated lines or terminals to prevent electrical shock.