![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/96/196af93e-b228-494d-939f-ae4bafeef5b7/196af93e-b228-494d-939f-ae4bafeef5b7-bgf.png)
Configuring a Remote Unit for Bridging and IP 2-7
5
When the automatic call has shut down (after approximately 90
seconds), enter CO IS AUTO IP to check the entries in the IP Autocall
table.
6
If there are no new entries in the ISDN Autocall table, check that the
name and ISDN number for the central site unit have been entered
correctly and then repeat steps 1–3 above.
7
Enter SAVE to save the new configuration.
Test the ISDN Numbers and IP Autocall Tables
Before testing the ISDN Number and IP Autocall entries, a manual call
must be made to the central site unit to complete the configuration.
1
Enter CO IS NU to display the ISDN Numbers screen.
2
Select the entry for the central site unit using the Arrow keys and
enter CALL
3
Enter REM to display the Remote Units screen and type [Ctrl]+[V] at
regular intervals to refresh the screen, until the name of the central
site unit appears in the list.
4
Enter CO IS NU to display the ISDN Numbers screen again.
5
Select the entry for the central site unit and enter CANC to cancel the
call.
6
Enter SAVE to save the new configuration.
Ensure that the ISDN call has been correctly cancelled.
See “Cancelling ISDN Calls” on page 2-13 for how to cancel the call if
it is still up.
To test that the IP Autocall and ISDN Number table entries are
correct:
1
Enter REM followed by the name of the central site unit. For example,
if the central site unit is named “london”, then enter REM london
■ If the tables are working correctly and the ISDN lines are
functioning properly, then the Enter Password screen on the
central site unit will be displayed. Go to step 8, below.
2
If the Enter Password screen on the central site unit is not displayed
within 30 seconds, press [Ctrl]+[D] to return to the local unit
management system.
Get_con.bk : BRID_IP.FRM Page 7 Friday, October 3, 1997 1:49 PM