Yamaha V565 Stereo System User Manual


 
19 En
Optimizing the speaker setting for your listening room (YPAO)
English
INTRODUCTION
ADDITIONAL
INFORMATION APPENDIX
PREPARATION
BASIC
OPERATION
ADVANCED
OPERATION
Flat
This adjusts each speaker to obtain the same
characteristics. Select this if your speakers have
similar qualities.
Front
This adjusts each speaker to obtain the same
characteristics as the front left and right speakers.
Select this if your front left and right speakers have
significantly better qualities than the other speakers.
5 Press nCursor n to select “Start” and then
press nENTER to start the setup procedure.
A countdown starts and a measurement starts in 10
seconds. A loud test tone is output during
measurement.
Notes
During the automatic setup procedure, do not perform any
operation on this unit.
Press nCursor k to cancel the automatic setup procedure.
When measurement is successfully completed,
“YPAO Complete” appears on the front panel display
and the results appear on the monitor.
SP
Displays the number of speakers connected to this unit in
the following order:
Total of Front and Center/Total of Surround and Surround
Back/Subwoofer
DIST
Displays the speaker distance from the listening position
in the following order:
Closest speaker distance/Farthest speaker distance
LVL
Displays the speaker output levels in the following order:
Lowest speaker output level/Highest speaker output level
Notes
If “ERROR” appears on the video monitor during “Auto Setup,”
measurement is canceled and the type of error is displayed. For details,
see “When an error message is displayed during measurement”
(page 20).
If problems occur during measurement, “WARNING (XX)” (xx indicates
the number of warning) appears above “RESULT” (see page 20).
6 Press nENTER to confirm the settings.
The speaker characteristics are adjusted according to
measurement results.
To cancel the operation, press nCursor l / h to
select “Cancel” and press nENTER.
When the following screen appears, remove the
optimizer microphone. “Auto Setup” is now
complete.
y
If you do not want to apply the measurement results, select “Cancel.”
Perform “Auto Setup” again if you change the number or positions of
speakers.
If you press nENTER before removing the optimizer microphone,
“1 Auto Setup” of “Speaker Setup” in the setup menu (see page 39) is
displayed.
Measurement takes about 3 minutes. To obtain precise
results, stay where you will not disturb the
measurement, such as to the side of or behind the
speakers or outside the room.
1 AutoSetup
RESULT
[ENTER]:Finish
SP:3/4/0.1
DIST:8.0/8.5ft
LVL:-3.5/+4.5dB
. >Set Cancel
[]/[]:Select
p[
The optimizer microphone is sensitive to heat. Store it
in a cool place and away from direct sunlight after
measurement. Do not leave it in a place where it will be
subjected to high temperatures such on an AV
component.
1 AutoSetup
AUTOSETUPComplete
[SETUP]:Exit

DisconnectMicrophone
PRESS[ENTER]