Wolf DCX-500I Home Theater System User Manual


 
Wolf Cinema Owner's Manual
3-62
Code Description
GENERAL
12 Software bug. Contact dealer/factory.
13 CRCerrorinashROM.Downloadnewsoftware.
14 Engineering-only programming is complete. Call Wolf Cinema, replace TIPM.
15 Attempting to download code without being in boot mode
16 Invalid interrupt. Power off/on. If it persists, contact dealer/factory.
17 User forced system to stay in boot mode
18 Jumper for programming boot not installed
LAMP FAILURES
20 Lamp turned on unexpectedly (fault related to ballast)
21 Lampairowlow,overheatingimminent
23 Cannot read valid ballast ID
26 Lamp 1 Interlock: lamp door open, lamp not installed
27 Can’t turn lamp on
28 Lamp turned off unexpectedly
29 Lamp ballast overheated
POWER AND COOLING
46 Red DMD temperature probe overheated
4C Projector shutdown due to critical error
C0 Lamp blower failure (lamp not turned on)
51 LVPS fan failed (Fan 1)
52 LVPS/ Red cooling fan failed (Fan 2)
53 DC lamp fan failed in 500W / 1kW models (Fan 3)
54 Red DMD heatsink fan failed on 1kW and 1.2kW models (Fan 4)
55 Green DMD heatsink fan failed on 1kW and 1.2kW models (Fan 5)
56 Blue DMD heatsink fan failed on 1kW and 1.2kW models (Fan 6)
57 TIPM fan failed (Fan 7)
58 TIPM fan failed (Fan 8)
TIPM (Image Processor)
60 Boot code CRC failed
61 Unable to program DigMux PLD
62 Unable to program Control PLD
63 Unable to program Bubks PLD
64 Unrecognized ROM type
65 WritetoashROMfailed
66 TIPM failure
67 Downloadedcodewillnott
68 Scaler communication problem
Clear system errors with
Exit
Exit
. If necessary, try resetting the
projector by powering it off and on again (cooling if necessary). For
detailed information, monitor the RS232 IN port. Contact dealer/
factory if error persists. Codes omitted from this table should not
appear in your projector.
Table 3.5 Error Codes
Section3►Operation
Code Description
BUILT-IN KEYPAD
70 Unable to access EEPROM on the built-in keypad
71 EEPROM memory re-initialization on the built-in keypad
PANEL DRIVER AND FORMATTER
80 Unrecognized Panel Driver
81 Unable to program device on Panel Driver
82 TIashdownloadfailure
83 TIashdownloadfailure
84 TIashdownloadfailure
85 TI-I2C write failure
86 One or more Formatters not responding — Probable Formatter s/w fault
87 Formatter reports RDRAM failure
88 Red modular Formatter communication failure
89 Green modular Formatter communication failure
8A Blue modular Formatter communication failure
93 Modular formatter architecture error
94 Modular formatter DMD mismatch
95 Modular formatter sequence mismatch
MISCELLANEOUS
A0 Unable to program the optional module
A1 Unable to power the optional module
A2 Unable to program the Dual Slot Backplane Module (DSBP)
A3 Unable to program the optional Post Processing Module (Warp module)