DLP Projector—User’s Manual
– 51 –
APPENDIX I
RS-232C Protocol
RS232 Setting
Baud rate: 9600
Parity
check:
None
Data bit: 8
Stop bit: 1
Flow
Control
None
Minimum delay for next command: 1ms
Control Command Structure
Header code Command code Data code End code
HEX Command Data 0Dh
ASCII ‘V’ Command Data CR
Operation Command
Note:
XX=00-98, projector's ID, XX=99 is for all projectors
Return Result P=Pass / F=Fail
n: 0:Disable/1: Enable/Value(0~9999)
Command Group 00
ASCII HEX Function Description Return Result
VXXS0001 56h Xh Xh 53h 30h 30h 30h 31h 0Dh Power On P/F
VXXS0002 56h Xh Xh 53h 30h 30h 30h 32h 0Dh Power Off P/F
VXXS0003 56h Xh Xh 53h 30h 30h 30h 33h 0Dh Resync P/F
VXXG0004 56h Xh Xh 47h 30h 30h 30h 34h 0Dh Get Lamp Hours Pn/F
VXXS0005n 56h Xh Xh 53h 30h 30h 30h 35h nh 0Dh Set Air filter timer n=0~999999 P/F
VXXG0005 56h Xh Xh 47h 30h 30h 30h 35h 0Dh Get Air filter timer n=0~999999 Pn/F
VXXS0006 56h Xh Xh 53h 30h 30h 30h 36h 0Dh System Reset P/F
VXXG0007 56h Xh Xh 47h 30h 30h 30h 37h 0Dh Get System Status
0: Reset
1:Standby
2:Operation
3:Cooling
Pn/F
VXXG0008 56h Xh Xh 47h 30h 30h 30h 38h 0Dh Get F/W Version Pn/F
VXXG0009 56h Xh Xh 47h 30h 30h 30h 39h 0Dh Get Alter EMail Pn/F
VXXS0009n 56h Xh Xh 53h 30h 30h 30h 39h nh 0Dh Set Alter Email
n=xxxxxx@xxxx.xxx.
xx