TOA Electronics TDX2 Speaker User Manual


 
22
8.3. Limiter Screen
Each output has an independent high performance limiter.
All limiters have an attack range of 0.3mS to 90mS, release times are 4, 8, 16 and
32 times the attack time and thresholds range from +22dB to –10dB in 1dB steps.
If the automatic limiter time constant option is in use, all limiter screens will say
‘automatic’ and the time constants will be set from the High pass filter frequency. A
table of dB to Vrms is in appendix 1.
The output meters are linked to the time constants of the limiters so true output
metering is achieved.
To adjust the limiter settings:
Select relevant channel by pressing the channel ‘GAIN’ button.
Use the ‘BACK’ and ‘NEXT’ keys to select the limiter screen.
Use the ‘FREQ’ control to adjust the attack time.
Use the ’Q’ control to adjust the release time.
Use the ‘GAIN’ control to adjust the limiter threshold.
OP2+5 Mid Limiter
Atk:4.0mS Rx16 +22dB