TOA Electronics A-9120DL Stereo Amplifier User Manual


 
51
(B12) Trigger setting (when Event classification is set to BASE)
EVENT01TR I
G
C- IN01
Set how to activate the selected Event.
NONE, C-IN01 – 04 (C-IN01 – 12 when C-001T is used), ZM-IN01 – 12* (default: C-IN01)
* Selectable only when the Remote controller type (p. 62-C26) is set to ZM-9001 or ZM-9002.
Setting Range
EVENT01 BASE 02 EVENT01 BASE 0 2
ENTER
Event number Confirmation indicator
(B11) BGM Event number selection (when Event classification is set to BASE)
Rotating the Parameter setting knob displays only the priority-8 inputs with the trigger function set to NONE
(normally BGM broadcasts) out of the Event numbers with Event classification set to ROUTE.
When the Enter key is pressed for confirmation, an asterisk [ ] is displayed on the right of the confirmed
number.
Up to 4 Event numbers can be set by repeating above-mentioned operations.
If the number of confirmed Event numbers exceeds 4, each number is erased in chronological order.
01 – 32 (default: 01)Setting Range
• C-IN01 to C-IN04 (C-IN01 to C-IN12 when the C-001T module is used):
Closing the designated control input terminal activates the Event. The control input terminals that
have already been set cannot be set.
• ZM-IN01 to ZM-IN12:
Pressing the designated control button of the ZM-9001 or ZM-9002 activates the Event.
Assigning a function to the button overwrites the previously set function on it if there is.
• NONE: External control cannot be used for activation.