TOA Electronics A-9120DL Stereo Amplifier User Manual


 
43
13.4.2. Input setting items
Use the Parameter setting knob for each parameter selection.
IN1–_______
(A1) Input channel name setting
The flashing portion is the cursor position for entering channel name characters.
Select a character from the alphanumeric character list by rotating the Parameter setting knob, then move the
cursor with the Right shift key.
Entering a new name overwrites the existing name, if there is.
To delete the character, select [ _ ] (under-bar) with the Parameter setting knob. Space cannot be entered.
Up to 7 characters can be used to set the name.
Even when an input channel name has been set, some setting screens display the channel number, not the
set name.
IN1–V
O
X–
O
FF
(A4) VOX ON/OFF setting (only in the normal matrix operation, when the D-001T/R is used)
Set the voice operated exchange (VOX) to ON or OFF.
• ON: Activates the set Event only when the audio signals are input to the module.
• OFF: The VOX function does not work.
(A2) Input sensitivity setting
(when the D-001T/R is used or when the AN-001T is used and ANC operation is set to ACTIVE)
IN1–S
E
NS I T I V I TY–10
Select the input sensitivity from the following 9 levels depending on the input sources:
Note
Setting the input sensitivity for the AN-001T's input channel automatically determines the reference level
which is a starting point for detecting the change in ambient noise level. The reference level can be fine
adjusted in Adjustment mode. (p. 68, p. 73-D14)
7 characters (default: IN1 – 8)
Setting Range
–60, –54, –48, –42, –36, –30, –24, –18, –10 dB (default)Setting Range
(A3) Phantom power ON/OFF setting
(when the D-001T/R is used or when the AN-001T is used and ANC operation is set to ACTIVE)
IN1–PHAN
TO
M
O
FF
Set the Phantom power to ON or OFF.
Note: When the module is the D-001R, this function can be set to ON but cannot be output.
• ON: Supplies the phantom power. (except D-001R)
• OFF: Does not supply the phantom power.
ON, OFF (default)
Setting Range