64
(C34) Setting the Event to be recalled when power is switched on
P
O
W
ER
ON
–EVENT LAST
Set the Event number to be activated when the unit's power is switched on.
Since no trigger is provided for Event activation at power-on, select the Event number that corresponds to
either the BGM Event or the BASE Event (with [ ] mark suffixed to its Event number), both set in the ROUTE
Event setting.
When LAST is selected, the unit returns to the state before power-off when turned on.
The unit operation depends on the trigger condition at power-on when there was an Event (interrupt
broadcast) or function (mute or emergency mute) being activated by a level trigger before power-off.
[When the function is set to EVENT:] (Only in the normal matrix operation)
LAST (default), 01 – 32 (only for Events set for ROUTE or BASE)
Setting Range
(C35) Setting the input channel to be recalled when power is switched on
P
O
W
ER
ON
–CH LAST
Set the input channel that is recalled at power-on.
Since no trigger is provided for input channel activation at power-on, select one from input signals (BGM) with
Priority 8 (with an asterisk suffixed to the channel number).
When LAST is selected, the unit returns to the state before power-off when turned on.
The unit operation depends on the trigger condition at power-on when there was an interrupt broadcast or
function (mute or emergency mute) being activated by a level trigger before power-off.
[When the function is set to CHANNEL:] (Only in the 1-channel or 2-channel output operation)
LAST (default), IN1 – 8
Setting Range
(C36) Operation method setting
M
O
DE
M
ATR I X
Set the operation method.
Only the methods that meet the operation requirements can be selected.
Each operation method can be selected when the following requirements are satisfied:
The 1-channel output operation (SINGLE-OUT) or normal matrix operation (MATRIX) can be selected when
the A-9060S, A-9120S, or A-9240SH without T-001T installed is used.
The 2-channel output operation (BGM/PAGE) or normal matrix operation (MATRIX) can be selected when the
A-9060DH or A-9120DH with ZP-001T but without T-001T installed is used.
On the conditions except above, the operation method cannot be selected but is fixed to the normal matrix
operation .
Changing the operation method here and confirming it with the Memory key initialize the settings that
contradict the reset operation method.
MATRIX, SINGLE-OUT, BGM/PAGESetting Range
[When the function is set to SUB-MODE:]