Tandberg Data LTO-2 HH Cassette Player User Manual


 
Tandberg LTO HH Installation and User Manual 35
8 App. A. LED-Indicator Behavior
8.1 LED-behavior During Normal Operation
Drive State
1
READY LED
(Green left)
ACTIVITY
LED
(Green)
CLEAN LED
(Amber)
FAULT LED
(Amber right)
LED-test.
The LEDs are turned ON in sequence
Power-On Self-Test
Starts in parallel with the LED-test .
ON
Flashing in about
12 sec
ON
After 12 sec:
Flashing during
cartridge load
ON
OFF
ON
OFF
LED-test.
The LEDs are turned ON one-by-one.
Power-On Self-Test starts in parallel
with the LED-test
2
.
ON ON ON ON
Diagnostic Activity / POST
4
Flashing OFF OFF OFF
Aborting Diagnostic Test Flashing
ON / OFF /
Flashing
ON
3
/ OFF Flashing
Cartridge not loaded. OFF OFF ON
3
/ OFF OFF
Cartridge loaded, no activity ON OFF ON
3
/ OFF OFF
Cartridge loaded, activity ON Flashing ON
3
/ OFF OFF
Cleaning OFF Flashing ON OFF
Cartridge loading or unloading OFF Flashing ON
3
/ OFF OFF
Unrecoverable drive failure ON / OFF OFF ON
3
/ OFF Flashing
5
Firmware download
in progress
Flashing OFF ON
3
/ OFF OFF
Firmware update
in progress
Flashing Flashing ON
3
/ OFF OFF
Firmware download failure
6
Flashing Flashing ON
3
/ OFF Flashing
5
Over temperature
7
OFF OFF ON
3
/ OFF ON
Aborting Diagnostic Test Flashing ON / OFF ON
3
/ OFF Flashing
Media Error (wrong, write protected or
harmed media)
OFF Flashing ON
3
/ OFF Flashing