Solid State Logic 82S6XL090A Speaker User Manual


 
Page 22
XLogic E Signature™ Channel Owner’s Manual
Meter Calibration
Equipment Required: Calibrated audio oscillator and audio level meter
Test Signal: 1kHz sinewave @ +24dBu
Input and Output: Oscillator to Line Input and Output to the audio level meter
Unit Setup: 1. Set both Line Gain and Output Gain to indent (0dB).
2. Check for +24dBu output level.
Adjustment: 1. Adjust VR24 until the ‘+24’ meter LED is just illuminated.
2. Reduce oscillator level to +18dBu, then +12dBu etc. and check that the correct
meter LEDs light. At each point, reduce the level slightly using the Output Gain
control and check each LED extinguishes.
EQ Alignments
Equipment Required: Calibrated audio oscillator and audio level meter
Test Signal: Sinewave @ 0dBu, frequencies as specified below
Input and Output: Oscillator to Line Input and Output to the audio level meter
Unit Setup: 1. Set both Line Gain and Output Gain to indent (0dB). Check that the Filters and
Dynamics are switched out.
2. Switch the EQ in and release all other EQ switches.
3. Set all of the Q and Frequency controls fully anti-clockwise and all EQ gain
controls to their centre indent.
LF EQ – Maximum Gain
Adjustment: 1. Ensure that the BLK switch is released.
2. Set LF Gain to maximum and select LF BELL. Set the audio oscillator for 80Hz
and adjust LF Frequency to find the maximum level on the audio level meter.
3. Adjust VR4 for +15dBu ±0.25dB.
4. Switch BLK in and re-adjust LF Frequency for maximum level.
5. Adjust VR6 for +18dBu ±0.25dB.
6. Reset LF Gain to its centre indent position, release the BLK switch and de-select
LF BELL. Re-check the audio level meter for 0dBu.
LMF EQ – Maximum Gain
Adjustment: 1. Ensure that the BLK switch is released.
2. Set LMF Gain to maximum and LMF Q fully anti-clockwise. Set the audio
oscillator for 1kHz and adjust LMF Frequency to find the maximum level on the
audio level meter.
3. Adjust VR9 for +15dBu ±0.25dB.
4. Switch BLK in and re-adjust LMF Frequency for maximum level.
5. Adjust VR12 for +18dBu ±0.25dB.
6. Reset LMF Gain to its centre indent position and release the BLK switch. Re-
check the audio level meter for 0dBu.
HMF EQ – Maximum Gain
Adjustment: 1. Ensure that the BLK switch is released.
2. Set HMF Gain to maximum and HMF Q fully anti-clockwise. Set the audio
oscillator for 3kHz and adjust HMF Frequency to find the maximum level on the
audio level meter.
3. Adjust VR14 for +15dBu ±0.25dB.