3.2 Mounting
This unit is designed to be rack-mounted. It is 1 RU (44.5mm/1.75 inch) high, its depth is:
325 mm/12.8 inches not including heatsink.
365 mm/14.3 inches including heatsink
400 mm/15.75 inches including connectors
The XLogic E Signature Channel units incorporate reinforcement brackets into the chassis and so are suitable for
direct rack-mounting. A 1RU space should be left above each unit to ensure adequate ventilation.
3.3 Connection
There are five connectors on the rear panel:
OUTPUT (male XLR)
KEY IN (female XLR)
LINE IN (TRS jack socket)
LINK (TRS jack socket)
INPUT (female XLR)
The XLR labelled ‘INPUT’ is for microphone signals; the ‘LINE IN’ jack socket is for line level signals such as a
synthesiser or DAW output. Neither input is suitable for use with guitar pickups, piezo electric bugs etc.
If you have more than one unit, the dynamics side-chain of multiple units may be linked together by connecting
the ‘LINK’ jacks together using a mono or stereo jack-to-jack cable(s).
The ‘KEY IN’ XLR provides line level access to the dynamics side-chain to enable the dynamics to be keyed from
external sources.