SMC Networks M8501 Cassette Player User Manual


 
Troubleshooting
M8501 and M8502 ACL Tape Drive Installation and User’s Guide—529972-001
6-11
Fault Symptom Codes (FSCs)
Unknown 701E C, G Attempt to show detailed drive status of a
drive whose type is unknown.
The SCSI response
was not expected
701F C, G The command response from the SCSI
task in a remote module was unexpected.
The Flash response
was not expected
7020 C, G The command response from the Flash
task in a remote module was unexpected.
SCSI response not
matched to a known
command
7021 C, G A command response was received from
a SCSI task, but the original command
opcode could not be determined.
Unexpected state after
NonVolConfig cmd
7022 C, G After successfully completing a
NonVolCofigPut command, the current
state of the save operation was unknown
Unexpected state after
SCSI mode cmd
7023 C, G After successfully completing a
SCSIUpdateModeParameters command,
the current state of the save operation
was unknown.
Unexpected state after
SCSI init cmd
7024 C, G After successfully completing a
SCSIInitcommand, the current state of the
save operation was unknown.
Cartridge reject
recovery failed
8001 C, D, G The DLT drive failed to successfully load
a tape even after retries.
Drive Fan stalled 8002 C, D, G The fan in the drive hot-swap shoe is
either not installed or has stalled.
Drive load did not
complete
8003 C, D, G The drive failed to successfully load a
tape.
Invalid drive was
installed
8004 F One or more installed drives are of a type
either unknown or not supported in the
current ACL personality.
LTO unmask drive
failed
8005 F The LTO drive unmask operation failed.
LTO mask drive failed 8006 F The LTO drive mask operation failed.
LTO unload drive (In
load retry) failed
8007 F The LTO drive failed to unload a cartridge
during a load retry operation.
Is Drive Unloaded
Failed
8008 F The LTO drive failed to return status when
being polled for unloaded state.
Orphan cartridge
recovery failed
9001 C, D, G The master module could not successfully
return an orphan cartridge to a slot
location.
Master pass-thru opto
failed
9003 C, D, G The master module opto sensor was not
detected during the power-up pass-thru
module inventory.
Table 6-2. Fault Symptom Codes
Message FSC ERP