SMC Networks M8501 Cassette Player User Manual


 
Troubleshooting
M8501 and M8502 ACL Tape Drive Installation and User’s Guide—529972-001
6-5
Fault Symptom Codes (FSCs)
Open Doors Fault 2093 C, G Door open sensor time-out detected when
open door.
Open DLT Handle
Fault
2094 C, G Failed to open DLT handle.
No IP Address Found 20a0 C, G SMC router failed to get an IP address.
No IP Address Mode
Fault
20a1 C, G SMC router failed to detected static or ip
address Mode.
Unknown exchange
for the async
message
20b0 C, G Unexpected exchange detected when
process Messages.
Drive In Error 20c0 C, G Control failed to set SCSI id.
Drive In Error 20c1 C, G Control failed to installed drive.
Drive In Error 20c0 C, G Control failed to set SCSI id.
Drive In Error 20c1 C, G Control failed to installed drive.
Motor Fault Condition 3000 C, G One of the motors has been disabled and
could not be re-enabled.
Picker Tach Errors 3002 C, G Picker Tach errors were detected when
checking slots.
Bin Fetch Failure 3001 C, G Loader failed to fetch a cartridge from a
bin.
Drive Fetch Failure 3013 C, G Loader failed to fetch a cartridge from the
drive.
Drive Time-out Failure 3015 C, D, G Loader detects unload command time-
out.
Drive Status Failure 3016 C, D, G Detected drive error from fetch, stow and
wait for handle ok DLT drive operation.
Drive In Flux Time-out 3017 C, D, G Time-out waiting for drive to clear the flux
status.
Drive Load Retry
Failed
3018 C, G LTO drive fail to load, detected in drive
task.
Drive OpenDoor
Failed
3019 C, G Failed open DLT door.
Drive Close Door
Failed
301A C, G Failed close DLT drive door.
Drive Communication
Error
301B C, D, G Intertask send, receive failed.
Drive Get General
Status Fail
301C C, D, G Drive communication failed.
Drive Get Status 3 Fail 301D C, D, G NOT USED
Table 6-2. Fault Symptom Codes
Message FSC ERP