SMC Networks M8501 Cassette Player User Manual


 
Troubleshooting
M8501 and M8502 ACL Tape Drive Installation and User’s Guide—529972-001
6-6
Fault Symptom Codes (FSCs)
Undefined Config 3020 C, G In loader, unexpected config, not a
Thunder or Lightning.
Orphan Cartridge not
flowed
3030 C, G The loader could not successfully stow an
orphan cartridge to a bin.
Chassis S/N
Mismatch. Previous
S/N retained
3031 G The serial number scanned from the
barcode label doesn't match the value
stored in non-volatile memory.
Chassis S/N
Character count is not
correct
3032 G A valid serial number barcode label could
not be read.
Chassis S/N did not
scan
3033 G A valid serial number barcode label could
not be read
Chassis S/N save
operation failed
3034 G The serial number scanned from the
barcode label could not be saved to non-
volatile memory.
Motor Firmware Error 3040 C, G The loader task detected an unexpected
status and could not recover (internal
target error).
Loader Received
Invalid Command
3041 C, G The loader task received an unexpected
command and could not recover (internal
target error).
Motor Firmware Error 3042 C, G The loader task detected an unexpected
status and could not recover (internal
target error).
Missing Magazine 3050 F In diag, no magazine installed for diag to
run.
No Cartridges In ACL 3051 F No cartridge available for diag to run.
Too Many Cartridges 3052 F Unable to run cart or drive cycle, loader is
full with cartridges.
Need 1 Drive
Minimum
3054 F No available drive to run diag.
Invalid Magazine Type 3057 F Unsupported Magazine type detected.
Magazine Type
Change Not Handled
3058 F Unsupported magazine type detected.
Drive Type Not
Supported
3059 F Unsupported drive type detected.
Diag Fetch, Drive not
loaded
305b F Diag: No cartridge present for a fetch.
Diag Time-out waiting
for drive empty, ready
305d F Fetch, time-out waiting for drive unload.
Table 6-2. Fault Symptom Codes
Message FSC ERP