23
INSTALLER
WIRING INSTRUCTIONS
RJ-45 Connections
The CAT-5 T568A wiring standard shown on
the right is used for the RJ-45 terminations.
Keypad Wiring
For the UNO-S1 keypad, the following connec-
tions are used to terminate the CAT-5 wire to the
110 punchdown on the keypad:
CAT-5 WIRE COLOR TYPE
Brown . . . . . . . . . . . . . . . . . . . +12V
Brown/White . . . . . . . . . . . . . . +12V
Green . . . . . . . . . . . . . . . . . . Ground
Green/White . . . . . . . . . . . . Status In
Orange . . . . . . . . . . . . . . . . . Ground
Orange/White. . . . . . . . . . . . . IR Out
Blue . . . . . . . . . . . . . . . . . . . COM A
Blue/White . . . . . . . . . . . . . . COM B
• To determine the amount of CAT-5 wire
required for the system installation, first
decide how many keypads will be used, then
determine the distance between each intend-
ed keypad location to the intended CAM6.6
location. The maximum recommended wire
run length is 250 feet for each UNO-S1
Keypad.
• Make sure that the entire wire path
between keypads and CAM6.6 is clear and
not obstructed by a floor ceiling joist, or
masonry wall which can’t be drilled through.
• Confirm ahead of time that you can drill an
outlet hole easily and in an unobtrusive spot
to connect wires with the CAM6.6.
• Label wires with keypad and room location.
This simplifies CAM6.6 hook-up once the key-
pads and speakers are installed.
Speaker Wiring
Standard 16-gauge 4-conductor stranded
speaker wire can be run up to to 125 feet;
14-gauge wire can be run up to 250 feet.
When running wire, pay particular attention to
the following areas:
• Avoid locations concealing pipes, heating
ducts and AC wiring in the general vicinity.
• Avoid running wires close to house electri-
cal wiring for any distance. If you have to run
them parallel, make sure to space the wires
at least two feet from the AC line.