Subaru Robin Power Products 13OOOT Cassette Player User Manual


 
Function
Warning lamp
Electric starter control
Fail-safe function
Self checking function
for warning lamp bulb
Description of Operation
When the lubrication oil pressure drops below the safety limit (Oil pres-
sure becomes less than 1 kg/cm2), the warning lamp turns on and off, and
the engine stops automatically. The warning lamp turns off after 3 minutes.
When the the engine started and reaches 1,050 rpm, the electric starter is
automatically stopped.
When the engine operating, the electric starter can not start.
When the key switch or the remote control switch is turned to ‘START”, the
fuel cut-off valve of the carburetor opens. When the key switch or the
remote control switch is turned to “STOP”, the fuel cut-off valve closes.
If the electric starter is locked by any reason, the electric starter is shut off
automatically after 3 seconds.
When the engine dose not start (engine speed dose not reach 1,050 rpm),
the electric starter is stopped after 21 seconds.
When the remote controller is connected, the electric starter dose not run
when the switch of remote controller is turned “OFF” even if the key switch
on the generator is turned to “START”.
When the key switch or remote control switch is turned to ‘START”, the
warning lamp lights up for a moment to indicate that the bulb for the warn-
ing lamp is normal.
4-2-7 IDLE CONTROL UNIT
(RGV12000 only)
The idle control unit has a function to check
that the generator has a load or not, then
decrease the engine rotation at no load or
increase it to the rated rotation.
The idle control unit releases throttle valve
when the applied load current exceeds
0.04A.
NOTE :
It is normal that the engine speed goes up for
a moment when you turn the key switch to
“STOP” while the Auto Idle Switch is in “ON”
position.
IDLE CONTROL UNIT
-9-