RS-A9/EW
103
5678
56
7
8
C
D
F
A
B
E
Note)
When adjusting by AMP unit alone (in the state removed from the main heat sink),
set the idling current to: 100 50mA.
Reason: Since the temperatures for Power TR vary according to their radiator capacity,
the adjustment values must be different with or without the main heat sink.
Intermediate Voltage
(Offset Voltage)
Item
Set volume value of Main Unit to
-
72dB and
-
both ends voltage of output when CD is
reproduced without recording. *1
Item
0 Below 30mV
Idling Current Set volume value of Main Unit to
-
72dB and
reproduce CD without recording. *1
Rated Value
150 50mA
*1 : 23 tracks of test disc(YEDS-7)