C1641M-A (3/05) 15
CONNECTIONS
Connections to the FT8301 transmitter and the FR8301 receiver are made on the rear panel of
the modules and consist of the following:
• Power connection
NOTE:
A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver
when used as a standalone module. A 12 VDC power supply is provided. If a 24 VAC
power supply is used, the power supply must be a Listed Direct Plug-In Power Unit
marked as Class 2 and rated as 24 VAC, 200 mA (minimum output).
• Fiber connection
•Video input connection (transmitter only)
•Video output connection (receiver only)
The following sections provide a view of FT8301 transmitter and FR8301 receiver connections.
CONNECTING THE FT8301 TRANSMITTER
Figure 8 illustrates FT8301 transmitter connections.
Figure 8.
FT8301 Transmitter Connections
POWER
CONNECTION*
FIBER OPTIC
CABLE
COAXIAL
CABLE
PIN 2
THE STRIPED WIRE OF THE SUPPLIED 12 VDC POWER SUPPLY CONNECTS
TO THE PIN 1 SCREW TERMINAL (DC+) OF THE POWER CONNECTOR.
THE OTHER WIRE CONNECTS TO THE SCREW TERMINAL (DC-).
*
12 /24