COMMUNICATION SETUP
Communication parameters are set to match those of the
connected devices and the system configuration.
Protocol
501 PROTOCOL
1. Move the cursor to PROTOCOL with the [] or [] but-
ton.
2. Select a suitable protocol with the JogDial.
The default is PS
DATA.
PS
DATA: Select when the communication chain uses
the PS
DATA protocol. This selection enables the
DATA terminal on the rear panel for communication.
VCR: Select when other than PS
DATA is used.
This selection enables the RS-232C terminal on the
rear panel for communication.
Note: Parallel use of the DATA and RS-232C terminals
is not possible.
Unit Address
502 UNIT ADDRESS
The unit address can be set either from the setup menu on
the monitor or using the DIP switch on the rear panel. The
address setup with the DIP switch has priority over the
setup on the monitor menu. Make certain to set DIP switch-
es #1 through #4 to OFF before setting the unit address on
the monitor.
1. Move the cursor to UNIT ADDRESS with the [] or []
button.
2. Select the address with the JogDial.
The default value is 1.
From 1 to 96: Set an address unique in the chain.
Baud Rate
503 BAUD RATE
DISPLAY SELECT
LCD CONTRAST
DISPLAY SELECT
LCD CONTRAST
1. Move the cursor to BAUD RATE with the [] or [] but-
ton.
2. Select the rate with the JogDial.
The default value is 9 600 bits per second.
4800: 4 800 bps
9600: 9 600 bps
19200: 19 200 bps
Data Bit
504 DATA BIT
1. Move the cursor to DATA BIT with the [] or [] button.
DISPLAY SELECT
LCD CONTRAST
UNIT ADDRESS 1
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
DISPLAY SELECT
LCD CONTRAST
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
COMMUNICATION SETUP
PROTOCOL PSDATA
UNIT ADDRESS 1
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
PROTOCOL PS
.
DATA
UNIT ADDRESS 1
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
SO 1
PROTOCOL PSDATA
UNIT ADDRESS 1
BAUD RATE 9600
DATA BIT 8