Niles Audio IPC-6 Stereo System User Manual


 
11
I
NTELLIGENT
P
OWER
C
ONTROLLER
5. Plug the IPC-6's AC power plug into an unswitched AC
power outlet. All the lights on the front panel will light for 2
seconds while the IPC-6s microprocessor checks all condi-
tions. If everything is ok, all but the red
POWER LED will turn
off. You are now ready to program your IPC-6.
Pre-amp
Surround Sound
Processor
Figure 2
Wiring Diagram
Blind
Controller
Lighting
Controller
Projector
Main Amp
Surround Amp
Center Amp
Equalizer
Screen
12
I
NTELLIGENT
P
OWER
C
ONTROLLER
Programming
You must program your IPC-6 in two steps.
1. The IPC-6s Accusense
TM
circuitry needs to measure the
on and the standby states of the device you have con-
nected to the sensing 120 volt AC outlet(s).
2. The IPC-6 also needs you to specify which outlets to acti-
vate along with their corresponding time delays.
Measuring Power “On” and “Standby” States.
Some devices (television sets, stereo receivers, etc) actually
have 3 power states. You can turn them on with a remote
control, you can place them in standby with a remote con-
trol, and you can use a manual power (or vacation) switch
to turn them completely off. You want the IPC-6 to measure
what happens to your device when you use the remote con-
trol. Unless you are sure there is not a third power state, use
the remote control to turn the device on and off.
1. Turn off the device(s) plugged into the A or "B" sensing
120 volt AC outlets.
2. In order to enter the PA programming mode, press and
hold down the
PROGRAM button on the front panel of the
IPC-6. While you are holding it down, press the A Trigger
button, then release both buttons.
The front panel LED's will sequence to the left and right
while the Accusense
TM
circuitry measures your device's stand-
N
O
C
O
M
N
C
3-30V
AC/DC
SWITCHED OUTLETS
AREL AY DC OUTREL AY DC OUT
TRIGGER
INPUTS
CONTROL OUTPUTS
123456
12 V
0.1 AMP
-
+
N
O
C
O
M
N
C
12 V
0.1 AMP
+- +-+
Niles Aud io
Corporation, Inc.
Miami, Florida USA
NILES
120 Volts AC 60Hz.
1500 Watts Max.
CONTROL
OUTPUT
RELAYS
C1 and
C2 rated
at 5 Amp s,
30 Volts
Max., AC
or DC.
C1
C2
CURRENT SENSE OUTLETS
B
AB
3-30V
AC/DC
-