Millennium Enterprises Stereo150 Stereo Amplifier User Manual


 
When ww= 7F(h) All module’s parameters will be requested.
When ww= 68(h) (position of the module minus 1), only that module’s parameters will be requested.
ww Requested Module’s parameter Values
When a Request All Current Parameter Values procedure is received, the Millennium will respond with a Respond All Current Parameter
Values procedure.
RECEIVE ALL CURRENT PARAMETER VALUES FOR CURRENT PRESET (24h)
SYS_HEAD, 24(h), nn1, nn2, ww1, ww2, mm1(1st), mm2(1st), aa1(1st), aa2(1st), dd1(1st)(1st), dd2(1st)1st, ... dd1(1st)(wth) ,dd2(1st)(wth),
... mm1(xth),...mm2(xth), aa1(xth), aa2(xth), dd1(xth)(1st), dd2(xth)(1st), ... dd1(xth)(wth),dd2(xth)(wth), F7(h)
When ww= 7F(h) All module’s parameters will be received.
When ww= 68(h) (position of the modules minus 1), only that module’s parameters will be received.
nn Number of Modules.
ww Modules User requested.
mm Indicates the beginning of the xth Module.
aa Number of available parameters in the FX Module.
dd Current value for the wth parameter.
The Receive All Current Parameter Values procedure is used to receive Parameter Values from the Millennium for the currently selected
program.
Warning: Sending data that was retrieved from a different preset will delete the memory. Be sure to only send data that was received from
the same preset.
REQUEST MODULE CONFIGURATION (25h)
SYS HEAD , 25 (h) , F7 (h)
When a Request Module Configuration procedure received, the Millennium will respond with a Respond Module Configuration procedure.
RESPOND MODULE CONFIGURATION (26h)
SYS HEAD , 26(h) , nn1, nn2, cc(1st)1,cc(1st)2, ee(1st)1, ee(1st)2, ... cc(nth)1, cc(nth)2 , ee(nth)1, ee(nth)2, F7(h)
nn Number modules present in the algorithm
cc Class I.D. of the nth module in the algorithm
ee I.D. number of the effect currently loaded in the nth module (see pg. 12 for ID numbers)
Class I.D. Numbers for millennium
00(h) Amplifier Type
01(h) 1/4 Effect Module
Johnson Millennium
User Guide
Section - 7 Appendix
93