Technical appendix
Cabling
CAT5
The DCS 6000 system uses CAT5, CAT5e or
CAT6 FTP or STP cables with screened RJ45
connectors.
EIA 568-B wiring shall be used.
It is important to use only FTP or STP
(screened) cables and screened RJ45 connectors
and not UTP cable, which is unscreened.
How to wire a CAT5 (EIA 568-B) Cable:
Pin
Function Connector #1
Connector #2
1 In-going + ORG/WHT ORG/WHT
2 In-going - ORG ORG
3 +48V GRN/WHT GRN/WHT
4 0V BLU BLU
5 0V BLU/WHT BLU/WHT
6 +48V GRN GRN
7 Outgoing - BRN/WHT BRN/WHT
8 Outgoing + BRN BRN
Note. If other colour codes are used then the four
pairs are connected as follows:
Pair 1: Pin 1 & 2
Pair 2: Pin 3 & 6
Pair 3: Pin 4 & 5
Pair 4: Pin 7 & 8
The phase of the pairs must be correct and the
wiring spec. as stated in CAT5 (EIA 568-B) have to
be followed.
Note: CAT6 cables can normally only be
terminated in sockets (female) and not in cable
plugs. CAT6 should thus only be used for long
cable draws terminating in wall outlets or patch
panels.
Analogue out (XLR3 male)
Pin
Signal Cable type
1 Ground
2 In phase signal
3 Out phase signal
DIS type #2914
or 2 x 0,25 mm
2
shielded.
Accessories (not supplied)
EC 6000-..5 Connection Cable 0.5 m......................10 03 12500
EC 6000-01 Connection Cable 1 m.........................10 03 13101
EC 6000-02 Connection Cable 2 m.........................10 03 13201
EC 6000-05 Connection Cable 5 m.........................10 03 13501
EC 6000-10 Connection Cable 10 m.......................10 03 14102
EC 6000-20 Connection Cable 20 m.......................10 03 14202
EC 6000-50 Connection Cable 50 m.......................10 03 14502