Integra MZA-4.7 Speaker System User Manual


 
11
Controller Termination
The recommended wiring and color scheme is shown in Fig 2.
Use the Standard 568-B color code for the CAT5E termination to the Controller – see Table 1. Although it is possible
to daisy chain controllers we recommend “home runs” of CAT5E cable with a maximum cable length of 200m.
Note:
Some IR receivers have an Amplifier On indicator, their “On” terminal should be connected to the zone’s AMP
ON output not to the controller interface ports “Data” terminal.
CAT5E cable used to
connect controllers
to MZA-4.7
Fig 2
Orange and Green
White/Green
White/Orange
White/Blue
Pin # Wire Color Keypad function
1 White/Orange +12V DC supply
2Orange 0V supply
3 White/Green IR output
4 Blue nc
5 White/Blue Data input
6 Green 0V supply
7 White/Brown nc
8 Brown nc
Table 1